Hometronic – An Overview
Important information on: Operating modes and functions
Installation of the collection relay (HS 20/30) has no effect on the
maximum number of devices at the Hometronic Manager HCM
200d.
Thermostat control with boiler feedback via HR 80 and
HC60NG (valve position-based)
With need-based boiler feedback, all HR 80s send information on
their valve position to the Hometronic Manager. When necessary,
the Hometronic Manager sends the boiler request to relay
HC60NG, which switches the boiler on.
See also Chapter "Installing boiler relay" on Page 52.
Analog output (TW)
The Hometronic Manager can be connected to a Honeywell
controller (MCR 35/40/200 or Panter) and regulate the heat gen-
erator as needed. The connection diagram can be found in the
installation instructions of the Hometronic Manager.
Regulation of the heat generator occurs depending on either the
room setpoints or the valve position.
The following parameters must be set for this:
Analog output (TW)
Dependent on valve position
(only with HR 80)
Dependent on room setpoint
22
Setpoint
OFF (default setting)
ON