Thermostat Control With Boiler Feedback; Installing Collection Relay - Honeywell Hometronic HCM 200d Operation

Hometronic manager
Hide thumbs Also See for Hometronic HCM 200d:
Table of Contents

Advertisement

Operation

Thermostat control with boiler feedback

Thermostat control with boiler feedback
Basic information is found in Chapter "Boiler feedback" on
Page 21.

Installing collection relay

Installation of the collection relay (HS 20 or HS 30) has no effect
on the maximum number of devices at the Hometronic Manager
HCM 200d.
Example: Installing device switch HS 30 as a collection relay.
Activate binding at the HS 30 as described in the operating
instructions of the HS 30.
Change to the "Settings" submenu as described on Page 54.
Turn the Dial button until "Installation" is selected.
Press the Dial button.
The following text is displayed:
Turn the Dial button to the left
until "Boiler request" is se-
lected.
Press the Dial button.
The following text is displayed:
Turn the Dial button to the left
until "Thermostat" is selected.
Press the Dial button.
An "*" appears after the "Ther-
mostat" entry.
The device switch HS 30 is installed as a collection relay.