Operation
Thermostat control with boiler feedback
Thermostat control with boiler feedback
Basic information is found in Chapter "Boiler feedback" on
Page 21.
Installing collection relay
Installation of the collection relay (HS 20 or HS 30) has no effect
on the maximum number of devices at the Hometronic Manager
HCM 200d.
Example: Installing device switch HS 30 as a collection relay.
Activate binding at the HS 30 as described in the operating
►
instructions of the HS 30.
Change to the "Settings" submenu as described on Page 54.
►
Turn the Dial button until "Installation" is selected.
►
Press the Dial button.
►
The following text is displayed:
Turn the Dial button to the left
►
until "Boiler request" is se-
lected.
Press the Dial button.
►
The following text is displayed:
Turn the Dial button to the left
►
until "Thermostat" is selected.
Press the Dial button.
►
An "*" appears after the "Ther-
mostat" entry.
The device switch HS 30 is installed as a collection relay.