Help With Problems; Error Messages In Display - Honeywell Hometronic HCM 200d Operation

Hometronic manager
Hide thumbs Also See for Hometronic HCM 200d:
Table of Contents

Advertisement

Help with problems

Error messages in display

Error message
!
Please check the
clock
Factory reset
Cold start
Device No. lost
Cause/Remedy
Error message of a device.
Cause: Invalid value, radio problems or battery
empty.
Check the signal source and eliminate the cause
(see Chapter "Status display" on Page 43).
Weak batteries in a Hometronic Module.
Check the signal source and eliminate the cause
(see Chapter "Status display" on Page 43).
Set date and time (see Chapter "Setting date
and time" on Page 24).
The Hometronic Manager is started with the factory
settings if the data in the Hometronic Manager was
faulty or lost and no settings were saved.
Use the mounting instructions to re-install mod-
ules and rooms or call our Service Department.
The Hometronic Manager carries out a cold start if
the data in the Hometronic Manager were faulty or
were lost, but settings had been saved beforehand.
The saved settings are used. Any changes which
were carried out after the last saving process are
lost.
Carry out the last changes again.
Remove the batteries and insert them again.
If the message is still displayed, call the Service
Department.
The Hometronic Manager is disabled.
Reverse disabling (see Chapter "Disabling
Hometronic Manager" on Page 37).
Appendix
Help with problems
111