Faults
Fault
The temperature in a
room
is
controlled
incorrectly
No display at the
display
Functioning of the
Hometronic Manager
is not possible or
only
to
a
limited
extent
Failed binding
Failed boiler feed-
back
Cause/Remedy
The radio connection in the Hometronic system
may be faulty.
Check the fault display at the storey controller
►
and at the radiator controller.
The power supply is interrupted.
Check the power supply.
►
Call the Service Department or bring the device
►
to the After-Sales. Inform the After-Sales of the
software version number which you have noted
in the table on Page 26.
Remove interfering/shielding devices, for exam-
►
ple:
•
wireless headphones, loudspeakers, garage
door openers or remote control units
•
interfering objects from the immediate envi-
ronment
•
metal parts
Correct the installation site of the room tempera-
►
ture sensor if necessary.
Repeat the binding.
►
Incorrect parameter setting of parameter for boiler
feedback "Setp. demand".
Set the parameter correctly:
►
•
For setpoint-based boiler feedback via
HS 20/30: "Setp. demand" "ON".
•
For need-based boiler feedback from HR 80
via relay HC60NG: "Setp. demand" "OFF".
Appendix
Help with problems
113