Hometronic – An Overview
Important information on: Operating modes and functions
The following values are set:
Room temperature setpoint 20 °C
eco lowering value 3 °C
eco limit 18 °C
In eco mode, the room temperature is lowered from 20 °C to
17 °C.
If the eco limit is set to 21 °C for example, the room temperature
does not change with the same setpoint of 20 °C in eco mode.

Partial automatic mode

You can specify individually for the heating/cooling (H), shutters
(R) and lamps/devices (L) whether they are to be operated
manually or automatically.

Manual mode

In manual mode* all the automatic functions (time programs, sun
protection function, presence simulation, automatic brightness
control and others) are deactivated. The setpoints valid when the
operating mode was changed remain valid.

Functions

Presence simulation
Light and device switches simulate the switching processes of
the last 7 days. This function remains valid until a setpoint over-
writes the presence simulation.
Recording for the simulation is carried out automatically.
Wind protection
This function remains active as long as a wind sensor measures
high wind speeds in order to protect shutters or awnings against
damage through storms. These shutters or awnings cannot be
operated manually during this function.