IMPORTANT
A730 and A730x support for symbologies and parameters may differ. Refer to the table
below for details.
The registry keys in the table below are located under:
[HKEY_LOCAL_MACHINE\Software\Vocollect\Imager\Code 39]
Registry Key
Code39Activation
Code39Unconventional
Code39ReadingRange
Code39CodeMark
Code39CheckDigitVerification
Code39ReadingTolerance
Code39BarCodeLengthL1
Code39BarCodeLengthL2
Code39BarCodeLengthL3
Code39BarCodeLengthMode
Code39CheckDigitTransmission
Voice Device and Headset Hardware Reference Guide
Default
A730
Value
0x1
ü
0x0
ü
0x1
ü
0x2a
ü
0x0
ü
0x0
ü
0x0
ü
0x0
ü
0x0
ü
0x0
ü
0x0
ü
A730x
Description
Enables the Code 39 symbology.
ü
Allows decoding of  unconventional
Code 39 (large intercharacter spacing
X
or a large ratio between narrow and
wide elements).
Enables Vesta algorithm decoding for
ü
better read range.
A single character inserted before the
bar code data to indicate the
ü
symbology.
Enables various check digit
calculations, where
0 = disabled,
Are 4/5
1 = modulo 43,
supported?
2 = French CIP,
3 = Italian CPI,
4 = HIBC, and
5 = AIAG.
Tolerance for reading "hard to read"
bar codes, where
X
0 = high,
1 = medium, and
2 = low.
Length value L1. Range is 0x0 to 0xFF
ü
(0 to 255).
Length value L1. Range is 0x0 to 0xFF
ü
(0 to 255).
Length value L1. Range is 0x0 to 0xFF
ü
(0 to 255).
Length verification mode, where
0 = "L1 is min length",
1 = "L1, L2, L3 are fixed lengths" – Not
ü
supported on A730x,
2 = "L1 is min, L2 is max length".
Enable transmission of the check
ü
digit.
42