Code 93 - Honeywell A700 Hardware Reference Manual

Voice device and headset
Hide thumbs Also See for A700:
Table of Contents

Advertisement

Code 93

Support for the parameters in the table is labeled as follows:
= Parameter is supported and available via the Scanner Options tab in the device profile.
ü
X
= Parameter is not supported on this device.
NYI = Not Yet Implemented. These parameters should be considered unsupported, though
they can (with knowledge) be set via the CCI or advanced settings.
IMPORTANT
A730 and A730x support for symbologies and parameters may differ. Refer to the table
below for details.
The registry keys in the table below are located under:
[HKEY_LOCAL_MACHINE\Software\Vocollect\Imager\Code 93]
Registry Key
Code93Activation
Code93CodeMark
Code93BarCodeLengthL1
Code93BarCodeLengthL2
Code93BarCodeLengthL3
Code93BarCodeLengthMode
Code93UDSI
Code 39
Support for the parameters in the table is labeled as follows:
ü
= Parameter is supported and available via the Scanner Options tab in the device profile.
X
= Parameter is not supported on this device.
NYI = Not Yet Implemented. These parameters should be considered unsupported, though
they can (with knowledge) be set via the CCI or advanced settings.
41
Default
A730
Value
0x0
ü
0x44
ü
0x1
ü
0x0
ü
0x0
ü
0x0
ü
B6
ü
Voice Device and Headset Hardware Reference Guide
A730x
Description
Enables the Code 93 symbology.
ü
A single character inserted before the
bar code data to indicate the
ü
symbology.
Length value L1. Range is 0x0 to 0xFF
ü
(0 to 255).
Length value L2. Range is 0x0 to 0xFF
ü
(0 to 255).
Length value L3. Range is 0x0 to 0xFF
ü
(0 to 255).
Length verification mode, where
0 = "L1 is min length",
1 = "L1, L2, L3 are fixed lengths" – Not
ü
supported on A730x,
2 = "L1 is min, L2 is max length".
User-defined symbology identifier.
ü
Range is 0-4 characters.

Advertisement

Table of Contents
loading

This manual is also suitable for:

A700x

Table of Contents