Origin Parameter Backup - Mitsubishi Electric MELFA CR750 Series User Manual

Hide thumbs Also See for MELFA CR750 Series:
Table of Contents

Advertisement

13.1.6. Origin Parameter Backup

You can back up the parameters that make up the origin data. Also, you can transfer the backed-up data to
a robot controller.
Click the origin data screen [Backup origin parameter] button to display the screen.
[Save to file]
[Select file for writing
to robot]
Caution
When the password is registered in "Parameter" by robot controller's
security function, it is not possible to restore the origin data string to the robot
controller by "origin parameter backup" screen.
When the password is registered in "Parameter" by robot controller's security function, it is not
possible to restore the origin data string to the robot controller by "origin parameter backup" screen.
Restore the origin data
Please delete the password of robot controller's security function when you operate these. Please
refer to "13.7.3 Delete the Password" for the method of deleting the password.
The setting(register the password) and the release(delete the password) of robot controller's
security function can be used with this software version 2.0 or later. Please refer to "Table 13-15
Compliant version of this function and controller" for robot controller's compliant version.
13-253
Figure 13-8 Robot Origin Parameter Backup Screen
: This saves origin parameters read from a robot controller (displayed
parameters) to a file.
: Transfer origin parameters stored in a file to a robot controller.
When transferring to a CRn-500 series robot controller with edition H7 or
earlier, set "Teach" mode.
Item to which password of security function is registered.
Program
○ : Enable、 × : Disable
Parameter
File
×
13-253

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melfa cr700 seriesMelfa cr500 seriesMelfa rt toolbox2Melfa rt toolbox2 min

Table of Contents