27.
Example 1
The following example causes the ports to be checked every 3 seconds:
device-name(config monitor port)#period seconds 3
device-name(config monitor port)#
Example 2
The following example resets the temperature monitoring period to the default 60 seconds:
device-name(config monitor temperature C)#no period
device-name(config monitor temperature C)#
Setting Log Alert Notifications for a Specific Indicator
The log command, in Monitoring Configuration mode, enables logging alert notifications for
a specific indicator.
If log alert notification is enabled, an alert message is written to the log and history files
when:
the indicator's status is "Failed"
the indicator's measured value exceeds its configured limit
the indicator's measured value crosses a configured delta point.
By default, log messages are enabled.
Command Syntax
device-name(config monitor INDICATOR)#log {enable | disable}
Argument Description
enable
Enables the monitoring alerts.
disable
Disables the monitoring alerts.
Example
This example enables log reporting for power monitoring:
device-name(config monitor power)#log enable
Setting Trap Alert Notifications for a Specific Indicator
The trap command, in Monitoring Configuration mode, enables SNMP trap alert notification
for a single indicator.
If trap alerts are enabled, an SNMP trap is issued when:
the indicator's status is "Failed"
the indicator's measured value exceeds its configured limit
the indicator's measured value crosses a configured delta point.