26.
description : the_tank_is_full
type
: snmp-trap, lasttimesent: 01:36:29
community
: public
2. To display a particular RMON event:
device-name#show rmon event 1
Defining Alarm Conditions
rmon alarm counter
The rmon alarm counter command, in Global Configuration mode, defines RMON alarm
conditions. The no rmon alarm command with a specified index removes the specified
RMON alarm definitions. Without a specified index, no rmon alarm removes all defined
RMON alarms.
Command Syntax
device-name(config)#rmon alarm <alarm-index> counter <1-17> UU/SS/PP
<1-4294967295> {absolute|delta} <rising-threshold>
<rising-index>
<falling-index> OWNER
device-name(config)#no rmon alarm [<alarm-index>]
Argument Description
alarm-index
Alarm index, in the range <1-65535>.
If the index is new - alarm conditions are created. If the index already exists -
alarm conditions are updated.
1-17
Counter number, indicating one of the following:
1
2
3
4
5
6
7
8
9
10 Jabbers
11 Collisions
12 Pkts64Octets
13 Pkts65to127Octets
14 Pkts128to255Octets
15 Pkts256to511Octets
16 Pkts512to1023Octets
MN700004 Rev 01
Remote Monitoring
DropEvents
Octets
Pkts
BroadcastPkts
MulticastPkts
CRCAlignErrors
UndersizePkts
OversizePkts
Fragments
309
<falling-threshold>