Load Analyzer; Diagnostics Menu - ABB ACS560 Firmware Manual

General purpose drives
Table of Contents

Advertisement

94 Program features

Load analyzer

Peak value logger
The user can select a signal to be monitored by a peak value logger. The logger
records the peak value of the signal along with the time the peak occurred, as well as
motor current, DC voltage and motor speed at the time of the peak. The peak value is
sampled at 2 ms intervals.
Settings
Parameter group
36 Load analyzer

Diagnostics menu

The Diagnostics menu provides quick information about active faults, warnings, fault
history and I/O connection status. It also helps you to find out why the drive is not
starting, stopping or running at the desired.
• Active faults
on the fault codes, see list of
• Fault history
codes, see list of
• Active warnings
information on the warning codes, see list of
• I/O status
Settings
Menu
Diagnostics
(page 291).
0
: Use this view to see the currently active faults. For information
Fault messages
: Use this view to see the fault history. For information on the fault
Fault messages
on page 424.
: Use this view to see currently active warnings. For
0
: Use this view to see currently active I/O settings.
on page 424.
Warning messages
on page 412.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents