No.
Name/Value
Warning
31.05
External event 3
source
31.06
External event 3
type
Fault
Warning
31.07
External event 4
source
31.08
External event 4
type
Fault
Warning
31.09
External event 5
source
31.10
External event 5
type
Fault
Warning
31.11
Fault reset
selection
Not used
Not used
DI1
DI2
DI3
DI4
DI5
DI6
Timed function 1
Timed function 2
Timed function 3
Supervision 1
Supervision 2
Supervision 3
Other [bit]
Description
The external event generates a warning.
Defines the source of external event 3. See also parameter
31.06 External event 3
type.
For the selections, see parameter
source.
Selects the type of external event 3.
The external event generates a fault.
The external event generates a warning.
Defines the source of external event 4. See also parameter
31.08 External event 4
type.
For the selections, see parameter
source.
Selects the type of external event 4.
The external event generates a fault.
The external event generates a warning.
Defines the source of external event 5. See also parameter
31.10 External event 5
type.
For the selections, see parameter
source.
Selects the type of external event 5.
The external event generates a fault.
The external event generates a warning.
Selects the source of an external fault reset signal. The signal
resets the drive after a fault trip if the cause of the fault no
longer exists.
0 - > 1 = Reset
Note: A fault reset from the fieldbus interface is always
observed regardless of this parameter.
Not used.
Not used.
Digital input DI1
(10.02 DI delayed
Digital input DI2
(10.02 DI delayed
Digital input DI3
(10.02 DI delayed
Digital input DI4
(10.02 DI delayed
Digital input DI5
(10.02 DI delayed
Digital input DI6
(10.02 DI delayed
Bit 0 of
34.01 Timed functions status
Bit 1 of
34.01 Timed functions status
Bit 2 of
34.01 Timed functions status
Bit 0 of
32.01 Supervision status
Bit 1 of
32.01 Supervision status
Bit 2 of
32.01 Supervision status
Source selection (see
Terms and abbreviations
Parameters 259
31.01 External event 1
31.01 External event 1
31.01 External event 1
status, bit 0).
status, bit 1).
status, bit 2).
status, bit 3).
status, bit 4).
status, bit 5).
(see page 273).
(see page 273).
(see page 273).
(see page 266).
(see page 266).
(see page 266).
on page 162). -
Def/FbEq16
1
Inactive
(true)
Fault
0
1
Inactive
(true)
Fault
0
1
Inactive
(true)
Fault
0
1
Not used
0
1
2
3
4
5
6
7
18
19
20
24
25
26

Hide quick links: