Advertisement

Checking Fluid Level
1. Position machine on a level surface. Make sure ma-
chine has cooled down so fluid is cold.
2. Remove cap from reservoir and check level of fluid.
The fluid should be up to bottom of screen in filler neck.
3. If fluid level is low, slowly fill reservoir with appropri-
ate hydraulic fluid until level reaches bottom of screen.
DO NOT OVERFILL.
IMPORTANT: To prevent system contamination,
clean top of hydraulic fluid containers before punc-
turing. Make sure pour spout and funnel are clean.
4. Install reservoir cap. Wipe up any fluid that may
have spilled.

Towing Traction Unit

In case of emergency, the Greensmaster 3200/3200–D
can be towed for a short distance. However, Toro does
not recommend this as a standard procedure.
IMPORTANT: Do not tow the machine faster than 2
to 3 mph because drive system may be damaged. If
machine must be moved a considerable distance,
transport it on a truck or trailer.
1. Locate by–pass valve on hydrostat and rotate it 90 .
2. Before starting engine, close by–pass valve by ro-
tating it 90 . Do not start engine when valve is open.
Check Hydraulic Lines and Hoses
Keep body and hands away from pin hole
leaks or nozzles that eject high pressure
hydraulic fluid. Use cardboard or paper to
find hydraulic leaks. Hydraulic fluid escap -
ing under pressure can penetrate skin and
cause injury. Fluid accidentally injected
into the skin must be surgically removed
within a few hours by a doctor familiar with
this form of injury, or gangrene may result.
Hydraulic System
WARNING
GR 3200–D WITHOUT
LEAK DETECTOR
1.
Hydraulic oil cap
1.
By–pass valve
Inspect hydraulic lines and hoses daily for leaks, kinked
lines, loose mounting supports, wear, loose fittings,
weather deterioration and chemical deterioration. Make
all necessary repairs before operating.
Page 5 – 6
1
2
Figure 6
2.
Filler screen
1
2
Figure 7
2.
Hydrostat
Greensmaster 3200/3200–D