Backlap Switch

The backlap switch is located on the hydraulic manifold
(when the Backlap Kit is installed). It is normally open
and closes when the backlap knob is turn clockwise to
the backlap position.
1. With the engine off, disconnect electrical connector.
2. Check the continuity of the switch by connecting a
multimeter (ohms setting) across the connector termi-
nals.
3. Turn the backlap knob clockwise to the backlap
position while watching the multimeter. Continuity
should be made as the switch closes.
4.
Turn the backlap knob counterclockwise to the mow
position while watching the multimeter. Continuity
should be broken as the switch opens.
5. Reconnect the electrical connector.

Hour Meter

1. Connect the positive (+) terminal of a 12 VDC
source to the positive terminal of the hour meter.
2. Connect the negative (–) terminal of the voltage
source to the other terminal of the hour meter.
3. The hour meter should move a 1/10 of an hour in six
minutes.
4. Disconnect the voltage source from the hour meter.