Leak Detector

Operation
The leak detector system is designed to assist in the ear-
ly detection of hydraulic oil system leaks. If the oil level
in the main tank is lowered by 4 to 5 ounces, the level
switch in the leak detection tank will close. After a 1 se-
cond delay, the alarm will sound alerting the operator.
Expansion of oil from the normal heating of the hydraulic
oil during machine operation will cause oil to transfer into
the leak detection tank. The oil is allowed to return to the
main tank when the ignition switch is turned off (see Fig.
20, 21, and 22).
Greensmaster 3200/3200–D
FLUID LEVEL
COLD
SOLENOID
RETURN
É É É
VALVE
OPEN
É É É
É É É É É É
É É É
BEFORE START (oil cold)
FLUID LEVEL
WARM
SOLENOID
RETURN
VALVE
É É É
CLOSED
É É É
É É É
É É
É É
NORMAL OPERATION (oil warm)
FLUID LEVEL
WARM
SOLENOID
RETURN
VALVE
CLOSED
É É É
É É
É É É
É É
FLOAT DOWN, SWITCH CLOSED
(FLUID LEVEL DOWN 4 TO 5 OUNCES)
Page 6 – 29
FILLER CAP
SIGHT
WINDOW
NO SOUND
É É
É É
FLOAT RAISED
SWITCH OPEN
Figure 20
NO SOUND
É É
É É
É É
É É
É É
FLOAT RAISED
SWITCH OPEN
Figure 21
WARNING
BUZZER
SOUNDS
É É
É É
É É
LEAK ALERT!
Figure 22
Electrical System