40 Ampere Thermal Breaker
This device operates as a thermal overload. After the
device trips, time should be allowed for it to cool and re-
set.
1.
Verify continuity between the two terminals.
2.
Replace if necessary.
Figure 15
Fuse Block
Fuses can be removed to check continuity, The test me-
ter should read less than 1 ohm.
For the GR3200, fuses supply power tho the following
(Fig. 18):
1. The top 10 ampere fuse supplies power to terminals
1L and 1M of the solid state controller.
2. The middle 10 ampere fuse supplies power to termi-
nals 1J and 1K of the solid state controller.
3. The bottom 10 ampere fuse supplies power to termi-
nal B of the ignition switch.
For the GR3200–D, fuses supply power tho the follow-
ing (Fig. 19):
1. The top 10 ampere fuse supplies power to the run
and mow relays.
2. The middle 10 ampere fuse supplies power to the
raise and lower relays.
3. The bottom 15 ampere fuse supplies power to termi-
nal B of the ignition switch.
Electrical System
Page 6 – 28
THERMAL BREAKER
Figure 16
THERMAL BREAKER
Figure 17
Figure 18
Figure 19
Greensmaster 3200/3200–D