Checking Engine Oil

IMPORTANT: Check level of oil every 5 operating
hours or daily. Change oil after every 50 hours of
operation.
Crankcase capacity is approximately 3.2 qts. (3.0 L)
with filter.
1. Park machine on a level surface, engage parking
brake, and lower cutting units. Allow engine to run for at
least ten minutes to bring it to operating temperature,
then shut off the engine.
2. Remove dipstick and wipe it with a clean rag. Push
dipstick down into dipstick tube and make sure it is
seated fully. Pull dipstick out and check level of oil. If oil
level is low, add enough oil to raise level to FULL mark
on dipstick (Fig. 8).
3. If oil level is low, remove oil fill cap (Fig. 9) and grad-
ually add small quantities of oil, checking level frequent-
ly, until level reaches FULL mark on dipstick.
4. The engine uses any high–quality 10W30 detergent
oil having the American Petroleum Institute – API – "ser-
vice classification" CD.

Checking Cooling System

The cooling system is filled with a 50/50 solution of water
and permanent ethylene glycol antifreeze. Check level
of coolant at beginning of each day before starting the
engine. Capacity of cooling system is approximately 3.6
qts. (3.4 L).
CAUTION
1. Park machine on a level surface.
2. Check coolant level. Coolant should be between
lines on reserve tank, when engine is cold.
3. If coolant is low, remove reserve tank cap and add
a 50/50 mixture of water and permanent ethylene glycol
antifreeze. Do not overfill.
4. Install reserve tank cap.
Greensmaster 3200–D
1
1. Reserve tank
Page 4 – 7
Figure 8
1. Dipstick
1
Figure 9
1. Oil fill cap
Figure 10
2. Radiator cap