General Run and Transport Problems (GR3200)
Problem
Engine kills when the functional control lever is in the
MOW or TRANSPORT position with the operator in the
seat.
Battery does not charge.

Cutting Unit Operating Problems (GR3200)

Problem
Cutting units run (but should not) when raised.
However, they shut off with the cutting unit switch
Cutting units do not engage.
Electrical System
Possible Causes
Operator is sitting too far forward on the seat (seat
switch not depressed).
Seat switch, mow senor, or neutral sensor is faulty or
out of adjustment.
Seat switch wiring is loose, corroded, or damaged.
The ECU is faulty
Engine overheated.
Wiring to the charging circuits (see Wiring Schematics)
components is loose, corroded, or damaged.
Voltage regulator/alternator is faulty.
40 ampere thermal breaker is open.
The ECU is faulty
Battery is dead.
Possible Causes
The mow sensor is faulty.
Wiring to run/mow/backlap circuits (see Wiring
Schematics) components is loose, corroded, or
damaged.
Cutting units are not lowered.
Cutting unit lower/mow or traction speed/mow switch is
faulty.
The ECU is faulty.
Cutting solenoid valve S1 is faulty.
Page 6 – 18