Download Print this page

Warning Light Cluster (Gr3200-D) - Toro Greensmaster 3200 Service Manual

Hide thumbs Also See for Greensmaster 3200:

Advertisement

Warning Light Cluster (GR 3200–D)
Note: Individual light bulbs can be tested by removing
them from the lighting cluster and applying 12 VDC to
their wiring terminals.
Oil Pressure Light
The oil pressure light should come on when the ignition
switch is in the ON position with the engine not running.
Also, it should light with the engine running when the oil
pressure drops below 4 PSI (0.3 kg/cm
1. Disconnect green/blue wire from the oil pressure
switch.
2. Ground green/blue wire to the engine block.
3. Turn the ignition switch to ON; the light should come
on.
4. Turn the ignition switch to OFF. Connect green/blue
wire to the oil pressure switch.
High Temperature (Water) Shutdown Light
The temperature light should come on only if the high
temperature shutdown switch and relay have stopped
the engine when the coolant temperature is above
206 F (97 C). The ignition switch must be in either the
ON or START position for the light to come on.
1. Disconnect the blue wire from the high temperature
shutdown switch.
2. Ground the blue wire to the engine block.
3. Turn the ignition switch to ON; the light should come
on and the high temperature shutdown relay should
click.
4. Turn the ignition switch to OFF and connect the blue
wire to the high temperature shutdown switch.
Glow Light
The glow light should come on with the ignition in the
START position.
1. Turn the ignition switch to START; the light should
come on.
2. Turn the ignition switch to OFF.
Electrical System
Battery Light
The battery light should come on when the ignition
switch is in ON with the engine not running or with an im-
properly operating charging circuit while the engine is
running.
1. Turn ignition switch to ON; the light should come on.
2. Turn ignition switch to OFF.
2
).
Page 6 – 36
FRONT
OIL
(RED)
BATT
(AMBER)
1
2
A B C D E F
BACK
Figure 34
B
GLOW
E
BATT
F
OIL
A
WATER
Figure 35
Greensmaster 3200/3200–D
WATER
(RED)
GLOW
(AMBER)
6
5
C
D

Advertisement

loading

This manual is also suitable for:

Greensmaster 3200-d