2600-00CTEIGAA
Ver.
Caution When Opening and Closing Power Window Cover
Make sure to turn off the breaker connected to the RRH-P4 power before opening
or closing the power window cover of the RRH-P4.
If you open or close the power window cover when the breaker is turned on, it
may cause damage to the system, or cause an electric short circuit resulting in
severe injury.
Caution on Rain-proof Gasket Damage When Installing Window Cover
Be careful so as not to let the rain-proof gasket get damaged (broken or
incorrectly positioned). Check whether the rain-proof gasket is damaged before
closing the power window cover and the optic window cover.
IF the rain-proof gasket is damaged, replace the system (RRH-P4) with a new one.
Caution When Fixing Power Cable
If you do not use a stainless steel tie to fix the power cable and the power cable
bracket, the cable tension may cause a connection failure or leakage. Make sure
to fix the power cable using a stainless steel tie.
You may need to use a tool designated for fixing with a stainless steel tie.
Tool for fastening Stainless Steel tie
When fastening stainless steel tie, the tool (Equivalent to the following specifications)
is recommended to fix External power cable support bracket and power cable.
Ex) Manufacture-Dong A bestech