Samsung Smart MBS RRH-P4 Installation Manual page 156

Table of Contents

Advertisement

2600-00CTEIGAA
Ver.
ANNEX E. Pressure Terminal Assembly
Assembling Heat Shrink Tube
1) After assembling a pressure terminal, move the heat shrink tube, inserted to the cable, to the end of
pressure terminal copper tube.
2) Set the temperature of the heat gun to 356~392°F(180~200°C).
3) Locate a heat shrink tube to cover the entire copper tube of the pressure terminal.
4) Rotate a heat gun 360° to apply heat evenly to shrink the tube.
(Because the pressure terminal and the cable is hot due to the heat of a heating gun, be careful not to
have a burn.)
E-14
4.0
Figure E.10 Assembling Heat Shrink Tube
Heat Shrink Tube
Pressure Terminal
© SAMSUNG Electronics Co., Ltd.