Table 1.2 Minimum Allowed Cable Bend Radius - Samsung Smart MBS RRH-P4 Installation Manual

Table of Contents

Advertisement

2600-00CTEIGAA
Ver.
No
1
GV/CV/FR-8
2
Optic Cable
3
UTP/FTP/S-FTP Cable
4
1/2 in. Feeder Line (Indoor)
5
1/2 in. Feeder Line (Outdoor)
6
7/8 in. Feeder Line (Outdoor)
7
1 1/4 in. Feeder Line (Outdoor)
8
1 5/8 in. Feeder Line (Outdoor)
9
LMR-400
10
RG-316D
11
Hybrid
Cable
* If the allowed cable bend radius is specified by the manufacturer, comply with the bend radius specified.
Cable Binding
Cable binding involves fixing and arranging an installed cable using binding strings, cable
ties, binding lines, and ram clamps, etc.
Follow these guidelines when binding a cable.
Be careful not to damage the cable during binding.
Use appropriate cable binding tools according to the target location (indoor or outdoor,
etc.) and the use of the cable (power supply cable, optical cable, feeder line, etc.).
Do not let the cutting section of a cable tie and binding line, etc. be exposed to the
outside. This may cause damage to cables or personal injury. Make sure that the
cutting sections of cables are not exposed to the outside.
Trim the binding string so that you have about 1.97 in. (5 cm) of string left from the
knot. And insert the remaining string into the knot and make sure the knot does not
loosen.
If there is a potential danger of contact failure in a connector connection due to tension,
install the cable in the shortest distance.
© SAMSUNG Electronics Co., Ltd.
4.0

Table 1.2 Minimum Allowed Cable Bend Radius

Type
External diameter:
0.98 in. (25 mm)
External diameter:
1.06 in. (27 mm)
External diameter:
1.18 in. (30 mm)
External diameter:
1.26 in. (32 mm)
Smart MBS RRH-P4 Installation Manual/Ver.3.0
Min. Allowed Cable Bend Radius
8 times of the cable external diameter
20 times of the cable external diameter
4 times of the cable external diameter
1.26 in. (32 mm)
4.92 in. (125 mm)
9.84 in. (250 mm)
14.96 in. (380 mm)
19.69 in. (500 mm)
1 in. (25.4 mm)
4 in. (101.6 mm)
0.59 in. (15 mm)
11.81 in. (300 mm)
13.0 in. (330 mm)
15.35 in. (390 mm)
17.71 in. (450 mm)
Remarks
0.6/1 KV cable
-
PVC/LSZH, 4
Pair
RFS, LS
RFS, LS
RFS, LS
RFS, LS
RFS, LS
Installation
Repeated
-
-
-
-
-
1-9