2600-00CTEIGAA
Ver.
CHAPTER 2. Installation of RRH-P4
13) Insert the rain protection filler completely to cable gland body and fasten the cable
gland nut by torque 2.17 lbf.ft (30 kgf.cm) using torque wrench. After fixing nut,
confirm using the gap gauge that distance between cable gland body and nut is within
0.03 in. (1.0 mm).
* Insert cable when the unsheathed DC power cable outer jacket locate at the rain protection filter
protrusion.
2-42
4.0
Rain Protection Filler
Protrusion
Figure 2.32 Connecting RRH-P4 power cable (AWG8) (6)
Rain Protection Gasket
External Power Cable Support Bracket
Power Cable
(Hybrid cable, AWG8, 2C)
Rain Protection Filler
Cable Gland Nut
Gap: 0.03 in.
Cable Gland Nut
Power Cable Outer Jacket
(AWG8)
Gap Gauge