2.7 Connecting Ground Cable

2.7.1 Grounding RRH-P4

Follow the steps below to connect the RRH-P4 ground cable.
1) Install one ground cable (AWG8, GV 6 mm
at the bottom of RRH-P4.
2) Install the pressure terminal and the heat shrink tube at the end of the cable.
Pressure Terminal: 6 mm
Hole Distance: 0.63 in. (16 mm)
3) Place the pressure terminal at one end of the ground cable of RRH-P4 aligning with
the fixing holes and fix it using M6 SEMS.
(When being tighten by screw, apply 2.76~3.37 lbf.ft (38.16~46.64 kgf.cm) torque.)
'A'
2-24
4.0
2
, 2hole, 90°, Hole Diameter: 1.4 in. (6.3 mm),
RRH-P4
Ground Cable (AWG8, GV 6 mm
2
6 mm
Pressure Terminal
(2Hole, 90°, Hole diameter: 1/4 in.,
Hole distance: 0.63 in.)
Heat Shrink Tube (Green)
M6 × 10L SEMS
External Power Cable Support Bracket
Ground Cable (AWG8, GV 6 mm
From MGB (Main Ground Bar)
Figure 2.17 Connecting RRH-P4 Ground cable
2
× 1 C) from TGB to the ground terminal
2
× 1C)
2
× 1C)