Samsung Smart MBS RRH-P4 Installation Manual page 83

Table of Contents

Advertisement

2600-00CTEIGAA
Ver.
13) Insert the rain protection filler completely to cable gland body and fasten the cable
gland nut by torque 2.17 lbf.ft (30 kgf.cm) using torque wrench. After fixing nut,
confirm using the gap gauge that distance between cable gland body and nut is within
0.0 in. (0.0 mm).
* Insert cable when the end of heat shrink tube locates at the unsheathed DC power cable outer
jacket about 0.39 in. (10 mm) or less.
© SAMSUNG Electronics Co., Ltd.
4.0
Rain Protection Filler
Protrusion
0.39 in.(10 mm)
(AWG10, Φ 0.45~0.49 in. / Φ11.5~12.4 mm)
Figure 2.39 Connecting RRH-P4 power cable (AWG10) (6)
Smart MBS RRH-P4 Installation Manual/Ver.3.0
Rain Protection Gasket
External Power Cable Support Bracket
Power Cable
(Hybrid cable, AWG10, 2C)
Rain Protection Filler
Cable Gland Nut
Gap: 0.0 in.(0.0 mm)
Cable Gland Nut
Heat Shrink Tube
(Jelly type, 12/4)
DC Power Cable Outer Jacket
Gap Gauge
2-53

Advertisement

Table of Contents
loading

Table of Contents