2600-00CTEIGAA
Ver.
CHAPTER 2. Installation of RRH-P4
11) Insert power terminal protection cap to the installed power cable.
12) Align the pressure terminal of the power cable to the power terminal block for proper
polarity and fix it with M5 screw.
13) After fixing the pressure terminal, cover the power terminal block with power terminal
protection cap.
2-52
4.0
RTN
-48 V
Figure 2.38 Connecting RRH-P4 power cable (AWG10) (5)
Pressure Terminal
(Ring Type, Hole diameter: 0.2 in.)
Power Terminal Block Fixing Screw
Heat Shrink Tube
(-48 V: Blue, RTN: Red)
Power Terminal Protection Cap
Power Cable
(-48 V: Black, RTN: White/Black strip)