32bit data
No.
H0200
reserved
H0201
Output frequency (0-15 bit)
H0202
Output frequency (16-31 bit)
H0203
Setting frequency (0-15 bit)
H0204
Setting frequency (16-31 bit)
H0205
Motor rotation (0-15 bit)
H0206
Motor rotation (16-31 bit)
H0207
Load meter (0-15 bit)
H0208
Load meter (16-31 bit)
H0209
Positioning pulse (0-15 bit)
H020A
Positioning pulse (16-31 bit)
H020B
Watt-hour meter (1 kWh step) (0-15 bit)
H020C
Watt-hour meter (1 kWh step) (16-31 bit)
H020D
Watt-hour meter (0.1/0.01 kWh step) (0-15 bit)
H020E
Watt-hour meter (0.1/0.01 kWh step) (16-31 bit)
H020F
Position error (0-15 bit)
H0210
Position error (16-31 bit)
H0211
Position command (lower 16 bits)
H0212
Position command (upper 16 bits)
H0213
Current position (lower 16 bits)
H0214
Current position (upper 16 bits)
H0215 to
reserved
H03FF
706
APPENDIX
Description
Unit
Type
-
-
0.01 Hz
signed
0.01 Hz
signed
1 r/min
signed
0.1%
signed
1
signed
1 kWh
unsigned
0.1/0.01 kWh
unsigned
1
signed
1
signed
1
signed
-
-
Read/
write
-
R
R
R
R
R/W
R
R
R
R
R
-