(D) Operation command and frequency command
5.9.6

JOG operation

The frequency and acceleration/deceleration time for JOG operation can be set. JOG operation is possible in both
External operation and PU.
JOG operation can be used for conveyor positioning, test run, etc.
Pr.
Name
15
Jog frequency
D200
16
Jog acceleration/
F002
deceleration time
Note that these parameters are categorized as a simple mode parameter when the LCD operation panel or the parameter unit
is used. Setting of this parameter is enabled when the operation panel is connected and "0" is set to Pr.160 User group read
selection. (Refer to
page

The Pr.20 initial value is set to 60 Hz.
JOG operation using the external signals
• Operation can be started and stopped by the start signals (STF and STR signals) when the Jog operation selection (JOG)
signal is ON. (For the operation method, refer to
• While the JOGF or JOGR signal is input, Jog frequency setting (Pr.15) is used for operation. The rotation is forward while
the JOGF signal is input, and the rotation is reverse while the JOGR signal is input. (Direct JOG function)
• Use the JOG acceleration/deceleration time function (Pr.16) to set the acceleration/deceleration time for JOG operation.
• To use each signal, set the corresponding number selected from the following table in any of Pr.178 to Pr.189 (Input
terminal function selection) to assign the function to an input terminal.
Input signal
Pr.178 to Pr.189 settings
JOG
5 (Pr.185 initial value)
JOGF
57
JOGR
58
Output frequency (Hz)
Pr.20
Pr.15
setting range
JOG signal
Forward rotation STF
Reverse rotation STR
312
PARAMETERS
Initial value
Setting range
5 Hz
0 to 590 Hz
0.5 s
0 to 3600 s
259.)
page
Forward
rotation
Reverse
rotation
Pr.16
ON
ON
ON
Sets the frequency during JOG operation.
Sets motor acceleration/deceleration time during JOG
operation. For the acceleration/deceleration time, set the time
until the frequency
reference frequency is reached.
The acceleration/deceleration times cannot be set separately.
92.)
Output frequency (Hz)
Pr.20
Pr.15
setting range
Time
Pr.16
JOGF signal
JOGR signal
Description
set in Pr.20 Acceleration/deceleration

Forward
rotation
Time
Reverse
rotation
ON
ON