Increment
Monitor item
and unit
Option output
terminal status 1
(for
communication)

Motor thermal load
0.1%
factor
Inverter thermal
0.1%
load factor
PTC thermistor
0.01 kΩ
resistance
PID measured
0.1%
value 2
Cumulative
pulse

Cumulative pulse
overflow times

Cumulative pulse
(control terminal
option)

Cumulative pulse
overflow times
(control terminal
option)

Multi-revolution
1
counter

32-bit cumulative
1 kWh
power (lower 16 bits)
32-bit cumulative
1 kWh
power (upper 16 bits)
32-bit cumulative
0.01 kWh/
power (lower 16 bits)
0.1 kWh

32-bit cumulative
0.01 kWh/
power (upper 16 bits)
0.1 kWh

Remote output
0.1%
value 1
Remote output
0.1%
value 2
Remote output
0.1%
value 3
Remote output
0.1%
value 4
PID manipulated
0.1%
variable
Pr. setting
RS-485
H3C

61
H3D
62
H3E
64
H40
67
H43
71
H47
72
H48
73
H49
74
H4A
75
H4B
H4D
H4E
H4F
H50
87
H57
88
H58
89
H59
90
H5A
91
H5B
(M) Monitor display and monitor output signal
Negative
MODBUS
indication
RTU
(-)

Output terminal ON/OFF state of the
digital output option (FR-A8AY) and
40260
relay output option (FR-A8AR) can be

monitored via RS-485 communication
and the communication option.
Displays the accumulated heat value
of the motor thermal O/L relay.
40261
The motor overload trip (E.THM)
occurs at 100%.
Displays the accumulated heat value
of the inverter thermal O/L relay.
40262
The inverter overload trip (E.THT)
occurs at 100%.
Displays the PTC thermistor
resistance when Pr.561 PTC
40264
thermistor protection level ≠ 9999
(voltage monitor when Pr.561 =
9999).
Displays PID measured value even if
PID control operating conditions are
40267
not satisfied while the PID control is
enabled (Pr.128 ≠ "0").
(Refer to
The cumulative number of pulses is
displayed (for Vector control
40271

compatible plug-in option).
(Monitoring range: -32767 to 32767)
The number of the cumulative pulses
carrying overflow times is displayed
40272

(for Vector control compatible plug-in
option).
The cumulative number of pulses is
40273
displayed (for the FR-A8TP).

(Monitoring range: -32767 to 32767)
The number of the cumulative pulse
40274
overflow times is displayed (for the

FR-A8TP).
The multi-revolution encoder counter
is monitored when the FR-A8APS is
40275
installed. (The output voltage is
monitored when the FR-A8APS is not
installed.)
Displays the 32-bit cumulative power
40277
value in multiplies of 16 bits.
Monitoring can be performed via RS-
40278
485 communication and
communication options. (To find the
40279
monitor codes for each
communication option, refer to the
Instruction Manual of each
40280
communication option.)
40287
40288
Displays the setting values of Pr.656
to Pr.659 (analog remote output).
(Refer to
40289
40290
Displays the PID control manipulated
40291
amount.
(Refer to
Description
page
497)
page
386.)
page
497)
351
PARAMETERS
5
GROUP
M