Pr.
Name
92
Motor constant (L1)/d-axis inductance (Ld) 5C DC 0
93
Motor constant (L2)/q-axis inductance (Lq) 5D DD 0
94
Motor constant (X)
95
Online auto tuning selection
96
Auto tuning setting/status
100
V/F1 (first frequency)
101
V/F1 (first frequency voltage)
102
V/F2 (second frequency)
103
V/F2 (second frequency voltage)
104
V/F3 (third frequency)
105
V/F3 (third frequency voltage)
106
V/F4 (fourth frequency)
107
V/F4 (fourth frequency voltage)
108
V/F5 (fifth frequency)
109
V/F5 (fifth frequency voltage)
110
Third acceleration/deceleration time
111
Third deceleration time
112
Third torque boost
113
Third V/F (base frequency)
114
Third stall prevention operation level
115
Third stall prevention operation frequency
116
Third output frequency detection
117
PU communication station number
118
PU communication speed
PU communication stop bit length / data
119
length
120
PU communication parity check
121
Number of PU communication retries
122
PU communication check time interval
123
PU communication waiting time setting
124
PU communication CR/LF selection
125
Terminal 2 frequency setting gain frequency 19 99 1
126
Terminal 4 frequency setting gain frequency 1A 9A 1
127
PID control automatic switchover frequency 1B 9B 1
128
PID action selection
129
PID proportional band
130
PID integral time
131
PID upper limit
132
PID lower limit
133
PID action set point
134
PID differential time
135
Electronic bypass sequence selection
136
MC switchover interlock time
137
Start waiting time
138
Bypass selection at a fault
Automatic switchover frequency from
139
inverter to bypass operation
140
Backlash acceleration stopping frequency
141
Backlash acceleration stopping time
142
Backlash deceleration stopping frequency
143
Backlash deceleration stopping time
144
Speed setting switchover
145
PU display language selection
Acceleration/deceleration time switching
147
frequency
148
Stall prevention level at 0 V input
149
Stall prevention level at 10 V input
150
Output current detection level
151
Output current detection signal delay time
Instruction
code

5E DE 0
()
5F DF 0
()
60 E0 0
00 80 1
01 81 1
02 82 1
03 83 1
04 84 1
05 85 1
06 86 1
07 87 1
08 88 1
09 89 1
0A 8A 1
0B 8B 1
0C 8C 1
0D 8D 1
0E 8E 1
0F 8F 1
10 90 1
11 91 1
12 92 1
13 93 1
14 94 1
15 95 1
16 96 1
17 97 1
18 98 1
1C 9C 1
1D 9D 1
1E 9E 1
1F 9F 1
20 A0 1
21 A1 1
22 A2 1
23 A3 1
()
24 A4 1
()
25 A5 1
()
26 A6 1
()
27 A7 1
()
28 A8 1
29 A9 1
2A AA 1
2B AB 1
2C AC 1
2D AD 1
2F AF 1
30 B0 1
31 B1 1
32 B2 1
33 B3 1
Control method

Vector
Vector
Vector
Sensorless
Sensorless
Sensorless

()
()
()
Parameter
PM
PM
PM















