Mitsubishi Electric 800 Series Instruction Manual page 138

600v class specification inverter
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

5.2.2
Changing the control method
Set the control method and control mode.
V/F control, Advanced magnetic flux vector control, Real sensorless vector control, Vector control, and PM sensorless
vector control are the control methods available for selection.
The control modes are speed control, torque control, and position control.
These are set when selecting Advanced magnetic flux vector control, Real sensorless vector control, Vector control,
and PM sensorless vector control. Under Real sensorless vector control, select a control mode from the speed control
and torque control modes. Under Vector control, select a control mode from the speed control, torque control, and
position control modes.
• Select a control method and control mode by using Pr.800 (Pr.451) Control method selection.
• The control mode can be switched using the mode switching signal (MC).
Pr.
Name
71
Applied motor
C100
80
Motor capacity
C101
81
Number of motor poles
C102
83
Rated motor voltage
C104
84
Rated motor frequency
C105
800
Control method
G200
selection
451
Second motor control
G300
method selection

For the FR-A860-01080 or lower.

For the FR-A860-01440 or higher.

When a PM motor is selected by Pr.71, 75 Hz (for the motor capacity 15 kW or lower) or 100 Hz (18.5 kW or higher) is used.

V/F control is set when Pr.453 and Pr.454 = "9999".
Initial
Setting range
value
0 to 6, 13 to 16, 30, 33,
0
34, 8090, 8093, 8094,

9090, 9093, 9094
0.4 to 55 kW

9999
0 to 3600 kW

9999
2, 4, 6, 8, 10, 12
9999
9999
575 V
0 to 1000 V
10 to 400Hz
9999
9999
0 to 6
9
10 to 12
13, 14
20
20
100 to 106
109
110 to 112
110, 113, 114
0 to 6
10 to 12
13, 14
20
100 to 106
9999
110 to 112
110, 113, 114
9999
Control method
Description
By selecting a standard motor or constant-torque
motor, the thermal characteristic and motor constant
of each motor are set.
Set the applied motor capacity.
V/F control
Set the number of motor poles.
V/F control
Set the rated motor voltage (V).
Set the rated motor frequency (Hz).
The setting value of Pr.3 Base frequency is used.
Vector control
Vector control test operation
Real sensorless vector control
PM sensorless vector control
V/F control (Advanced magnetic flux vector control)
Vector control
Vector control, PM sensorless
vector control test operation
Real sensorless vector control
PM sensorless vector control
Vector control
Real sensorless vector control
PM sensorless vector control
V/F control (Advanced magnetic flux vector control)
Vector control
Real sensorless vector control
PM sensorless vector control
Advanced magnetic flux vector control when the
induction motor is selected in Pr.71.
As set in Pr.800 when the PM motor is selected in
Pr.71.
PARAMETERS

Fast-response
operation
Fast-response
operation
5

137

Hide quick links:

Advertisement