Mitsubishi Electric 800 Series Instruction Manual page 404

600v class specification inverter
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

Relationship between the analog input terminal function and the
calibration parameter
• Calibration parameter according to the terminal 1 function
Pr.868
Terminal function
Setting
0
Frequency (speed) setting
(initial
auxiliary
value)
1
Magnetic flux command
Regenerative driving
2
torque limit
3
Torque command
Stall prevention operation
level

4
/torque limit/torque
command
Forward/reverse rotation
5
speed limit
6
Torque bias input
9999
No function
• Calibration parameter according to the terminal 4 function
Pr.858
Terminal function
setting
0
(initial
Frequency command
value)
1
Magnetic flux command
Stall prevention operation
4
level

/torque limit
9999
No function

Perform stall prevention operation level bias/gain adjustment by using the Pr.148 Stall prevention level at 0 V input and Pr.149 Stall
prevention level at 10 V input.
To change the frequency for the maximum analog input (Pr.125, Pr.126)
• To change only the frequency setting (gain) for the maximum analog input voltage (current), set Pr.125 (Pr.126).
(Pr.902 to Pr.905 settings do not need to be changed.)
Bias setting
Pr.902 Terminal 2 frequency setting bias
frequency
Pr.902 Terminal 2 frequency setting bias
Pr.904 Terminal 4 frequency setting bias
frequency
Pr.904 Terminal 4 frequency setting bias
Pr.919 Terminal 1 bias command (torque)
Pr.919 Terminal 1 bias (torque)
Pr.919 Terminal 1 bias command (torque)
Pr.919 Terminal 1 bias (torque)
Pr.917 Terminal 1 bias frequency (speed)
Pr.917 Terminal 1 bias (speed)
Pr.919 Terminal 1 bias command (torque)
Pr.919 Terminal 1 bias (torque)
Bias setting
Pr.904 Terminal 4 frequency setting bias
frequency
Pr.904 Terminal 4 frequency setting bias
Pr.932 Terminal 4 bias command (torque)
Pr.932 Terminal 4 bias (torque)
Pr.932 Terminal 4 bias command (torque)
Pr.932 Terminal 4 bias (torque)
(T) Multi-Function Input Terminal Parameters
Calibration parameter
Pr.125 (Pr.903) Terminal 2 frequency setting
gain frequency
Pr.903 Terminal 2 frequency setting gain
Pr.126 (Pr.905) Terminal 4 frequency setting
gain frequency
Pr.905 Terminal 4 frequency setting gain
Pr.920 Terminal 1 gain command (torque)
Pr.920 Terminal 1 gain (torque)
Pr.920 Terminal 1 gain command (torque)
Pr.920 Terminal 1 gain (torque)
Pr.918 Terminal 1 gain frequency (speed)
Pr.918 Terminal 1 gain (speed)
Pr.920 Terminal 1 gain command (torque)
Pr.920 Terminal 1 gain (torque)
Calibration parameter
Pr.126 (Pr.905) Terminal 4 frequency setting
gain frequency
Pr.905 Terminal 4 frequency setting gain
Pr.933 Terminal 4 gain command (torque)
Pr.933 Terminal 4 gain (torque)
Pr.933 Terminal 4 gain command (torque)
Pr.933 Terminal 4 gain (torque)
Gain setting
Gain setting
403
PARAMETERS
5
GROUP
T

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents