Using two types of motors (RT signal, Pr.450)
• When using two types of motors with one inverter, set Pr.450 Second applied motor.
• The setting value "9999" (initial value) disables second applied motor.
• If Pr.450 ≠ 9999, the following parameters will be enabled by turning ON the Second function selection (RT) signal.
Function
Electronic thermal O/L relay
Applied motor
Control method selection
Motor capacity
Number of motor poles
Motor excitation current
Rated motor voltage
Rated motor frequency
Motor constant (R1)
Motor constant (R2)
Motor constant (L1)/d-axis inductance (Ld)
Motor constant (L2)/q-axis inductance (Lq)
Motor constant (X)
Auto tuning setting/status
Frequency search gain
Online auto tuning selection
Induced voltage constant (phi f)
Motor Ld decay ratio
Motor Lq decay ratio
Starting resistance tuning compensation
Starting magnetic pole position detection pulse width
Maximum motor frequency
Motor inertia (integer)
Motor inertia (exponent)
Motor protection current level
Torque current/Rated PM motor current
NOTE
• The RT signal is a second function selection signal. The RT signal also enables other second functions. (Refer to
• The RT signal is assigned to the terminal RT in the initial status. Set "3" in any of Pr.178 to Pr.189 (Input terminal function
selection) to assign the RT signal to another terminal.
• Changing the terminal assignment using Pr.178 to Pr.189 (Input terminal function selection) may affect the other
functions. Set parameters after confirming the function of each terminal.
CAUTION
 Make sure to set this parameter correctly according to the motor used. Incorrect setting may cause
the motor and inverter to overheat and burn.
Parameters referred to
???????
Pr.96 Auto tuning setting/status
Pr.100 to Pr.109 (Adjustable 5 points V/F)
Pr.178 to Pr.189 (Input terminal function selection)
Pr.684 Tuning data unit switchover
Pr.800 Control method selection
RT signal ON (second
Pr.51
Pr.450
Pr.451
Pr.453
Pr.454
Pr.455
Pr.456
Pr.457
Pr.458
Pr.459
Pr.460
Pr.461
Pr.462
Pr.463
Pr.560
Pr.574
Pr.738
Pr.739
Pr.740
Pr.741
Pr.742
Pr.743
Pr.744
Pr.745
Pr.746
Pr.860
page 426
page 598
page 415
page 426
page 137
(C) Motor constant parameters
RT signal OFF (first motor)
motor)
Pr.9
Pr.71
Pr.800
Pr.80
Pr.81
Pr.82
Pr.83
Pr.84
Pr.90
Pr.91
Pr.92
Pr.93
Pr.94
Pr.96
Pr.298
Pr.95
Pr.706
Pr.711
Pr.712
Pr.717
Pr.721
Pr.702
Pr.707
Pr.724
Pr.725
Pr.859
page
419.)
425
PARAMETERS