(A) Application parameters
Digital source (monitored item) selection
• Select the digital sources (input/output signals) to be set to Pr.1038 to Pr.1045 from the table below. When a value other
than the below, 0 (OFF) is applied for display.
Setting
Signal
value
name
0
1
STF
2
STR
3
AU
4
RT
5
RL
6
RM
7
RH
8
JOG
9
MRS
STP
10
(STOP)
11
RES
12
CS
21
X0
22
X1
23
X2
24
X3
25
X4
26
X5
27
X6
28
X7
29
X8
30
X9
31
X10
32
X11
33
X12
34
X13
35
X14
36
X15
37
DY
Trigger setting (Pr.1025, Pr.1035 to Pr.1037, Pr.1046, Pr.1047)
• Set the trigger generating conditions and trigger target channels.
Pr.1025
setting
0
Trace starts when inverter enters an fault status (protective function activated)
1
Trace starts when analog monitor satisfies trigger conditions
2
Trace starts when digital monitor satisfies trigger conditions
3
Trace starts when either of analog or digital monitor satisfies trigger conditions (OR)
4
Trace starts when both of analog or digital monitor satisfies trigger conditions (AND)
• Set the trigger generation conditions for the analog monitor.
Pr.1036
setting
Sampling starts when the analog data targeted for the trigger exceeds the value
0
specified at the trigger level
Sampling starts when the analog data targeted for the trigger has fallen below the value
1
specified at the trigger level

For Pr.1037, set the number obtained by adding 1,000 to the trigger level.
• Set the trigger generation conditions for the digital monitor.
Pr.1047
setting
0
Trace starts when the digital data targeted for the trigger turns ON
1
Trace starts when the digital data targeted for the trigger turns OFF
538
PARAMETERS
Remarks
For the details of the signals, refer to
page
415.
For the details of the signals, refer to
the Instruction Manual of FR-A8AX
(option).
Trigger generating conditions
Trigger generation conditions
Trigger generation conditions
Setting
Signal
value
name
101
RUN
102
SU
103
IPF
For the details of the signals, refer to
104
OL
page
105
FU
106
ABC
107
ABC2
121
DO0
122
DO1
123
DO2
For the details of the signals, refer to
124
DO3
the Instruction Manual of FR-A8AY
(option).
125
DO4
126
DO5
127
DO6
128
RA1
For the details of the signals, refer to
129
RA2
the Instruction Manual of FR-A8AR
(option).
130
RA3
Remarks
370.
Selection of trigger
target channel
Pr.1035
Pr.1046
Pr.1035, Pr.1046
Pr.1035, Pr.1046
Trigger level setting
Set the trigger level by
Pr.1037 (-400% to 400%)
