(M) Monitor display and monitor output signal
Increment
Monitor item
and unit
PLC function user
monitor 1
PLC function user
According
monitor 2
to the
SD1215
setting
PLC function user
monitor 3
Station number
1
(RS-485 terminals)
Station number
1
(PU)
Station number
1
(CC-Link)
Energy saving
effect
Changeable
by
parameter
Cumulative energy
setting.
saving
PID set point
0.1%
PID measured
0.1%
value
PID deviation
0.1%
Input terminal
status
Output terminal
status
Option input
terminal status

Option output
terminal status

Option input
terminal status 1
(for
communication)

Option input
terminal status 2
(for
communication)

350
PARAMETERS
Pr. setting
RS-485
40
H28
41
H29
42
H2A
43
H2B
44
H2C
45
H2D
46
H2E
50
H32
51
H33
52
H34
53
H35
54
H36
H0F

55

H10

56

57

H3A

H3B

Negative
MODBUS
indication
RTU
(-)

Displays the arbitrary monitoring item
40240
using the PLC function.
Displays the following special register
40241
values.
SD1216: Displays in No.40
SD1217: Displays in No.41
SD1218: Displays in No.42
40242
(Refer to the PLC Function
Programming Manual.)
Displays which station number (0 to
31) can currently be used for
40243
communication from the RS-485
terminal block.
Displays which station number (0 to
31) can currently be used for
40244
communication from the PU
connector.
Displays which station number (0 to
31) can currently be used for CC-Link
40245
communication.
Displays "0" when the FR-A8NC is
not connected.
40246
For manufacturer setting. Do not set.
Displays the energy saving effect
40250
monitor.
Conversion to power saving, average
power saving, price display, and
percentage display can be done
40251
using parameters.
(Refer to
40252
Displays the set point, measured
value, and deviation under PID
40253
control.
(Refer to
40254
Displays input terminal ON/OFF state
of the inverter. (Refer to the
40215

instruction manual of the operation
panel.)
Displays output terminal ON/OFF
state of the inverter. (Refer to the
40216

instruction manual of the operation
panel.)
Displays input terminal ON/OFF state
of the digital input option (FR-A8AX)
on the DU. (Refer to the instruction
manual of the operation panel.)
Displays output terminal ON/OFF
state of the digital output option (FR-
A8AY) and the relay output option
(FR-A8AR) on the DU. (Refer to the
instruction manual of the operation
panel.)
Input terminal X0 to X15 ON/OFF
state of the digital input option (FR-
40258
A8AX) can be monitored via RS-485

communication and the
communication option.
Input terminal DY ON/OFF state of
the digital input option (FR-A8AX) can
40259
be monitored via RS-485

communication and the
communication option.
Description
page
365.)
page
497)