Input Terminal Function Selection - Mitsubishi Electric 800 Series Instruction Manual

600v class specification inverter
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

5.12.8

Input terminal function selection

Use the following parameters to select or change the input terminal functions.
Pr.
Name
178
STF terminal function
T700
selection
179
STR terminal function
T7001
selection
180
RL terminal function
T702
selection
181
RM terminal function
T703
selection
182
RH terminal function
T704
selection
183
RT terminal function
T705
selection
184
AU terminal function
T706
selection
185
JOG terminal function
T707
selection
186
CS terminal function
T708
selection
187
MRS terminal function
T709
selection
188
STOP terminal function
T710
selection
189
RES terminal function
T711
selection
Pr.
Name
699
Input terminal filter
T740

The initial value is for standard models.

The initial value is for separated converter types.
Input terminal function assignment
• Using Pr.178 to Pr.189, set the functions of the input terminals
• Refer to the following table and set the parameters.
Signal
Setting
name
Pr.59 = 0 (initial value)
0
RL
Pr.59  0
Pr.270 = 1, 3, 11, 13
Pr.59 = 0 (initial value)
1
RM
Pr.59  0
Pr.59 = 0 (initial value)
2
RH
Pr.59  0
Second function selection
3
RT
Pr.270 = 1, 3, 11, 13
Initial
value
60
STF (Forward rotation command)
61
STR (Reverse rotation command)
0
RL (Low-speed operation command)
1
RM (Middle-speed operation command)
2
RH (High-speed operation command)
3
RT (Second function selection)
4
AU (Terminal 4 input selection)
5
JOG (Jog operation selection)
CS (Selection of automatic restart after
6
instantaneous power failure, flying start)
24
MRS (Output stop)

10
X10 (Inverter run enable signal)

STP (STOP) (Start self-holding
25
selection)
62
RES (Inverter reset)
Initial
Setting range
value
5 to 50 ms
9999
9999
Function
Low-speed operation command
Remote setting (setting clear)

Stop-on-contact selection 0

Middle-speed operation command
Remote setting (deceleration)

High-speed operation command
Remote setting (acceleration)

Stop-on-contact selection 1

(T) Multi-Function Input Terminal Parameters
Initial signal
Description
Set the time to delay the input terminal response.
No input terminal filter
Related parameter
Pr.4 to Pr.6, Pr.24 to Pr.27,
Pr.232 to Pr.239
Pr.59
Pr.270, Pr.275, Pr.276
Pr.4 to Pr.6, Pr.24 to Pr.27,
Pr.232 to Pr.239
Pr.59
Pr.4 to Pr.6, Pr.24 to Pr.27,
Pr.232 to Pr.239
Pr.59
Pr.44 to Pr.51, Pr.450 to Pr.463,
Pr.569, Pr.832, Pr.836, etc.
Pr.270, Pr.275, Pr.276
Setting range
0 to 20, 22 to 28, 32, 37,
42 to 48, 50 to 53, 57 to 60, 62,
64 to 74, 76, 77 to 80, 85,
87 to 89, 92 to 96, 9999
0 to 20, 22 to 28, 32, 37,
42 to 48, 50 to 53, 57 to 59, 61,
62, 64 to 74, 76, 77 to 80, 85,
87 to 89, 92 to 96, 9999
0 to 20, 22 to 28, 32, 37, 42 to
48, 50 to 53, 57 to 59, 62, 64 to
74, 76, 77 to 80, 85, 87 to 89,
92 to 96, 9999
Refer to
page
314
279
463
314
279
314
279
419
463
415