(T) Multi-Function Input Terminal Parameters
Signal
Setting
name
4
AU
Terminal 4 input selection
5
JOG
Jog operation selection
Selection of automatic restart after instantaneous power
failure, flying start
6
CS
Electronic bypass function
7
OH
External thermal relay input
15-speed selection
8
REX
(Combination with multi-speeds of RL, RM, and RH)
9
X9
Third function selection
10
X10
Inverter run enable signal (FR-CC2 connection)
11
X11
FR-CC2 connection, instantaneous power failure detection
12
X12
PU operation external interlock
13
X13
External DC injection brake operation start
14
X14
PID control valid terminal
15
BRI
Brake opening completion signal
16
X16
PU/External operation switchover (External operation with X16-ON)
Load pattern selection forward/reverse rotation boost (For
17
X17
constant-torque with X17-ON)
18
X18
V/F switchover (V/F control with X18-ON)
19
X19
Load torque high-speed frequency
20
X20
S-pattern acceleration/deceleration C switchover
22
X22
Orientation command for Vector control compatible options
23
LX
Pre-excitation/servo ON
Output stop
24
MRS
Electronic bypass function
STP
25
Start self-holding selection
(STOP)
26
MC
Control mode switchover
27
TL
Torque limit selection
28
X28
Start-time tuning start external input
32
X32
External fault input
37
X37
Traverse function selection
42
X42
Torque bias selection 1
43
X43
Torque bias selection 2
44
X44
P/PI control switchover (P control with X44-ON)
45
BRI2
Second brake sequence open completion
46
TRG
Trace trigger input
47
TRC
Trace sampling start/end
48
X48
Power failure stop external
50
SQ
Sequence start
51
X51
Fault clear
Cumulative pulse monitor clear for Vector control
52
X52
compatible options
53
X53
Cumulative pulse monitor clear (control terminal option) (for FR-A8TP)
57
JOGF
JOG forward rotation command
58
JOGR
JOG reverse rotation command
59
CLRL
NET position pulse clear
Forward rotation command (Assignable to the STF terminal
60
STF
(Pr.178) only)
Reverse rotation command (Assignable to the STR terminal
61
STR
(Pr.179) only)
62
RES
Inverter reset
64
X64
PID forward/reverse action switchover
65
X65
PU/NET operation switchover (PU operation with X65-ON)
66
X66
External/NET operation switchover (NET operation with X66-ON)
Command source switchover (Command by Pr.338, Pr.339
67
X67
enabled with X67-ON)
68
NP
Simple position pulse train sign
69
CLR
Simple position droop pulse clear
416
PARAMETERS
Function



Related parameter
Pr.267
Pr.15, Pr.16
Pr.57, Pr.58, Pr.162 to Pr.165,
Pr.299, Pr.611
Pr.57, Pr.58, Pr.135 to Pr.139, Pr.159
Pr.9
Pr.4 to Pr.6, Pr.24 to Pr.27,
Pr.232 to Pr.239
Pr.110 to Pr.116
Pr.30, Pr.70, Pr.599
Pr.30, Pr.70
Pr.79
Pr.10 to Pr.12
Pr.127 to Pr.134, Pr.575 to Pr.577
Pr.278 to Pr.285
Pr.79, Pr.340
Pr.14
Pr.80, Pr.81, Pr.800
Pr.270 to Pr.274
Pr.380 to Pr.383
Pr.350 to Pr.369
Pr.850
Pr.17
Pr.57, Pr.58, Pr.135 to Pr.139,
Pr.159
Pr.250
Pr.800
Pr.815
Pr.95
Pr.592 to Pr.597
Pr.840 to Pr.845
Pr.840 to Pr.845
Pr.820, Pr.821, Pr.830, Pr.831
Pr.641 to Pr.649
Pr.1020 to Pr.1047
Pr.1020 to Pr.1047
Pr.261 to Pr.266, Pr.294, Pr.668
Pr.414
Pr.414
Pr.635
Pr.15, Pr.16
Pr.15, Pr.16
Pr.291, Pr.419 to Pr.430, Pr.464
Pr.250
Pr.250
Pr.75
Pr.127 to Pr.134
Pr.79, Pr.340
Pr.79, Pr.340
Pr.338, Pr.339
Pr.291, Pr.419 to Pr.430, Pr.464
Pr.291, Pr.419 to Pr.430, Pr.464
Refer to
page
393
312
515
448
317
314
419
608
608
291
599
488
457
291
593
137
466
274
473
599
418
448
421
137
154
444
419
469
175
175
164
457
533
533
526
531

227
312
312
226
421
421
244
488
291
291
301
225
226

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents