Mitsubishi Electric 800 Series Instruction Manual page 224

600v class specification inverter
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

Connection diagram
• Connection with the positioning module of RD75P type MELSEC iQ-R series is also available.
Three-phase
AC power
Forward stroke end
Reverse stroke end
Pre-excitation (servo on)
Torque limit
Positioning module
command
MELSEQ iQ-R RD75P
( ± 10V)
FLS
RLS
DOG
STOP
CLEAR
PULSE F
*7
PULSE R
CLRCOM
PG024
PG0COM
RDYCOM
COM
READY

The pin number differs according to the encoder used. Speed control, torque control, and position control by pulse train input are available with
or without the Z-phase being connected.

Connect the encoder so that there is no looseness between the motor and motor shaft. Speed ratio must be 1:1.

Earth (ground) the shield of the encoder cable to the enclosure using a tool such as a P-clip. (Refer to

For the complementary, set the terminating resistor selection switch to the OFF position (initial status). (Refer to

A separate external power supply of 15 V is necessary according to the encoder power specification. When the encoder output is the differential
line driver type, only 5 V can be input. When the 24 V power supply of the FR-A8AL is used, the power is supplied to the encoder through
terminal PG24. When the 5 V/12 V power supply of the FR-A8AL is used, the power is supplied to the encoder through terminal PGV. Do not use
the external power supply simultaneously with the 5 V/12 V power supply or the 24 V power supply. Make the voltage of the external power
supply the same as the encoder output voltage, and connect the external power supply between terminals PG and SD.

Assign the function using Pr.178 to Pr.184, Pr.187 to Pr.189 (Input terminal function selection).

The pulse signal from the position module is available for both open collector and differential line driver. However, the connections are different.
(The following figure shows an example for differential line driver.) For the connection method, refer to the Instruction Manual of the FR-A8AL.
Operation outline
• If the pre-excitation/servo ON (LX) signal is turned ON, output shutoff is canceled and the position control preparation ready
(RDY) signal is turned ON after 0.1 second. When the STF signal (forward stroke end) or the STR signal (reverse stroke
end) is turned ON, the motor rotates according to the command pulse. When the forward (reverse) stroke end signal is
turned OFF, the motor does not rotate in the corresponding direction.
Forward rotation command (STF)
Reverse rotation command (STR)
Position control preparation ready (RDY)
Forward rotation pulse train (PGP/PP)
Reverse rotation pulse train (PGN/NP)
Inverter
MCCB
R/L1
S/L2
T/L3
supply
STF
STR
LX
*6
SD
(+)
1
5
(-)
FR-A8AL
SD
Complementary
CR
Differential
PP
PGP
Terminating
resistor
NP
ON
PGN
SD
OFF
VDD
*4
FPZ2
VDD
OPC
RDY
Forward rotation
Actual rotation
Reverse rotation
Base signal
Servo on (LX)
 
 
 
0.1s
In-position (Y36)
Position control under vector control
Vector-control-dedicated motors
U
U
V
V
IM
W
W
E
Earth
(Ground)
PA
*1
A
PAR
B
PB
C
PBR
D
Encoder
F
PZ
G
PZR
PG
S
SD
R
PG24
*3
*5
*2
page
60.)
page
60.)
PARAMETERS
5
223