(D) Operation command and frequency command
5.9.4

Reverse rotation prevention selection

This function can prevent reverse rotation fault resulting from the incorrect input of the start signal.
Pr.
78
Reverse rotation prevention
D020
selection
• Set this parameter to limit the motor rotation to only one direction.
• This parameter is valid for all of the reverse rotation and forward rotation keys of the operation panel and of the parameter
unit, the start signals (STF, STR signals) via external terminals, and the forward and reverse rotation commands through
communication.
5.9.5

Frequency setting via pulse train input

A pulse train input to the terminal JOG can be used to set the inverter's speed command.
Moreover, speed synchronized operation of an inverter can be performed by using the pulse train output together with
the terminal JOG.
Pr.
Name
291
Pulse train I/O selection
D100
384
Input pulse division
D101
scaling factor
385
Frequency for zero input
D110
pulse
386
Frequency for maximum
D101
input pulse

Function assigned to Pr.185 JOG terminal function selection.
308
PARAMETERS
Name
Initial value
0
Initial value
0
0
0 Hz
60 Hz
Setting range
0
1
2
Setting
range
Pulse train input
(terminal JOG)
0
JOG signal

1
Pulse train input
10
JOG signal

11
Pulse train input
20
JOG signal

21
Pulse train input
100
Pulse train input
0
Pulse train input disabled
Division ratio on the input pulse. The frequency resolution on
1 to 250
the input pulse changes according to this setting.
0 to 590 Hz Sets the frequency when the input pulse is zero (bias).
0 to 590 Hz Sets the frequency when the input pulse is maximum (gain).
Description
Both forward and reverse rotations
allowed
Reverse rotation disabled
Forward rotation disabled
Description
Pulse train output
(terminal FM)
FM output
FM output
High-speed pulse train output (50%
duty)
High-speed pulse train output (50%
duty)
High-speed pulse train output (ON
width is fixed)
High-speed pulse train output (ON
width is fixed)
High-speed pulse train output (ON
width is fixed)
Output of pulse train input as is