Mitsubishi Electric 800 Series Instruction Manual page 110

600v class specification inverter
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

Pr.
Pr.
group
USB communication station
547
N040
number
USB communication check time
548
N041
interval
549
N000
Protocol selection
NET mode operation command
550
D012
source selection
PU mode operation command
551
D013
source selection
552
H429
Frequency jump range
553
A603
PID deviation limit
554
A604
PID signal operation selection
555
E720
Current average time
556
E721
Data output mask time
Current average value monitor
557
E722
signal output reference current
560
A712
Second frequency search gain
561
H020
PTC thermistor protection level
Energization time carrying-over
563
M021
times
564
M031
Operating time carrying-over times
Second motor excitation current
565
G301
refraction point
Second motor excitation current
566
G302
low speed scaling factor
569
G942
Second motor speed control gain
570
E301
Multiple rating setting
571
F103
Holding time at a start
A680
573
4 mA input check selection
T052
574
C211
Second motor online auto tuning
575
A621
Output interruption detection time
576
A622
Output interruption detection level
577
A623
Output interruption cancel level
592
A300
Traverse function selection
593
A301
Maximum amplitude amount
Amplitude compensation amount
594
A302
during deceleration
Amplitude compensation amount
595
A303
during acceleration
596
A304
Amplitude acceleration time
597
A305
Amplitude deceleration time
599
T721
X10 terminal input selection
Name
Setting range
0 to 31
0 to 999.8 s, 9999
0, 1
0, 1, 9999
1 to 3, 9999
0 to 30 Hz, 9999
0 to 100%, 9999
0 to 3, 10 to 13
0.1 to 1 s
0 to 20 s
0 to 500 A
0 to 3600 A
0 to 32767, 9999
0.5 to 30 kΩ, 9999
(0 to 65535)
(0 to 65535)
0 to 400 Hz, 9999
0 to 300%, 9999
0 to 200%, 9999
0 to 3
0 to 10 s, 9999
1 to 4, 9999
0 to 2
0 to 3600 s, 9999
0 to 590 Hz
900 to 1100%
0 to 2
0 to 25%
0 to 50%
0 to 50%
0.1 to 3600 s
0.1 to 3600 s
0, 1
Parameter list (by parameter number)
Minimum
setting
Initial value
increments
1
0
0.1 s
9999
1
0
1
9999
1
9999
0.01 Hz
9999
0.1%
9999
1
0
0.1 s
1 s
0.1 s
0 s
0.01 A


Inverter rated
current
0.1 A


1
9999
0.01 kΩ
9999
1
0
1
0
0.01 Hz
9999
0.1%
9999
0.1%
9999
1
2
0.1 s
9999
1
9999
1
0
0.1 s
1 s
0.01 Hz
0 Hz
0.1%
1000%
1
0
0.1%
10%
0.1%
10%
0.1%
10%
0.1 s
5 s
0.1 s
5 s
0

1
1

PARAMETERS
Parameter List
Refer
to
page
Pr.
584
List
584
546
301
301
330
488
488
267
267
267
426,
522
317
347
347
595
595
143
249
283
411
444
488
488
5
488
469
469
469
469
469
469
608
109

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents