Mitsubishi Electric 800 Series Instruction Manual page 147

600v class specification inverter
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

Control method
Pr.
Name
13
Starting frequency
15
Jog frequency
18
High speed maximum frequency
20
Acceleration/deceleration reference frequency 60 Hz
22
Stall prevention operation level
37
Speed display
55
Frequency monitoring reference
56
Current monitoring reference
71
Applied motor
80
Motor capacity
81
Number of motor poles
84
Rated motor frequency
116
Third output frequency detection
125
Terminal 2 frequency setting gain frequency
(903)
126
Terminal 4 frequency setting gain frequency
(905)
144
Speed setting switchover
240
Soft-PWM operation selection
263
Subtraction starting frequency
Power failure deceleration time switchover
266
frequency
374
Overspeed detection level
386
Frequency for maximum input pulse
505
Speed setting reference
Current average value monitor signal output
557
reference current
820
Speed control P gain 1
821
Speed control integral time 1
Torque control P gain 1 (current loop
824
proportional gain)
Torque control integral time 1 (current loop
825
integral time)
870
Speed detection hysteresis
Regeneration avoidance compensation
885
frequency limit value
Energy saving monitor reference (motor
893
capacity)
918
Terminal 1 gain frequency (speed)
1121 Per-unit speed control reference frequency

Initial value for the FR-A860-01080 or lower.

Initial value for the FR-A860-01440 and higher.

110% for SLD, 120% for LD, 150% for ND, and 200% for HD (Refer to Pr.570 Multiple rating setting

The Pr.702 Maximum motor frequency is used as the maximum motor frequency. When Pr.702 ="9999 (initial value)", the Pr.84 Rated motor
frequency is used as the maximum motor frequency.
NOTE
• If PM parameter initialization is performed in rotations per minute (
and the monitored items are also set and displayed in rotations per minute.
146
PARAMETERS
Induction
motor
0
Pr.998
(initial value)
0.5 Hz
5 Hz
120 Hz

60 Hz

150%

0
60 Hz
Inverter rated
current
0
9999
9999
9999
60 Hz
60 Hz
60 Hz
4
1
60 Hz
60 Hz
9999
60 Hz
60 Hz
Inverter rated
current
60%
0.333 s
100%
5 ms
0 Hz
6 Hz
Inverter rated
capacity
60 Hz
120 Hz

60 Hz

Setting
PM motor
PM motor
(rotations per
(frequency)
minute)
8009
9009
Pr.84 10%
Pr.84 10%
Pr.84 10%
Pr.84 10%
Pr.84
Pr.84
150%

0
Pr.84
Pr.84
Pr.859
Pr.859
Pr.84
Pr.84
Pr.84
Pr.84
Pr.84
Pr.84
Pr.81 +100
Pr.81
0
Pr.84
Pr.84
Pr.84
Pr.84
Maximum motor
Maximum motor
frequency+10 Hz
frequency+10 Hz

Pr.84
Pr.84
Pr.84
Pr.84
Pr.859
Pr.859
30%
0.333 s
100%
20 ms
8 r/min
0.5 Hz
Pr.84 10%
Pr.84 10%
Motor capacity (Pr.80)
Pr.84
Pr.84
Maximum motor
Maximum motor
frequency
frequency

page
= "
Pr.998
8009 or 9009"), the parameters not listed in the table
Setting
increments
8109
8009,
0, 8109,
9109
9009
9109
1 r/min
0.01 Hz
1 r/min
0.01 Hz
1 r/min
0.01 Hz
1 r/min
0.01 Hz
0.1%
1
1 r/min
0.01 Hz
0.01 A

0.1 A

1
0.01 kW

0.1 kW

1
1 r/min
0.01 Hz
1 r/min
0.01 Hz
1 r/min
0.01 Hz
1 r/min
0.01 Hz
1
1
1 r/min
0.01 Hz
1 r/min
0.01 Hz
1 r/min
0.01 Hz

1 r/min
0.01 Hz
0.01 Hz
0.01 A

0.1 A

1%
0.001 s
1%
0.1 ms
1 r/min
0.01 Hz
1 r/min
0.01 Hz
0.01 kW

0.1 kW

1 r/min
0.01 Hz
1 r/min
0.01 Hz

―: Not changed
249.)