Schedule Power Save Plus (EnergyWise) on Cisco IP Phone
Field
Phone On Time
Phone Off Time
Phone Off Idle Timeout
Enable Audible Alert
Cisco IP Phone 7821, 7841, and 7861 Administration Guide for Cisco Unified Communications Manager 10.0
(SIP)
116
Description
Determines when the phone automatically turns on for the days that are in the Enable Power Save
Plus field.
Enter the time in this field in 24-hour format, where 00:00 is midnight.
For example, to automatically power up the phone at 7:00 a.m. (0700), enter 7:00. To power up
the phone at 2:00 p.m. (1400), enter 14:00.
The default value is blank, which means 00:00.
The Phone On Time must be at least 20 minutes later than the Phone Off Time. For
Note
example, if the Phone Off Time is 7:00, the Phone On Time must be no earlier than 7:20.
The time of day that the phone powers down for the days that are selected in the Enable Power
Save Plus field. If the Phone On Time and the Phone Off Time fields contain the same value, the
phone does not power down.
Enter the time in this field in 24-hour format, where 00:00 is midnight.
For example, to automatically power down the phone at 7:00 a.m. (0700), enter 7:00. To power
down the phone at 2:00 p.m. (1400), enter 14:00.
The default value is blank, which means 00:00.
Note
The Phone On Time must be at least 20 minutes later than the Phone Off Time. For
example, if the Phone Off Time is 7:00, the Phone On Time must be no earlier than 7:20.
The length of time that the phone must be idle before the phone powers down.
The timeout occurs under the following conditions:
• When the phone was in Power Save Plus mode, as scheduled, and was taken out of Power
Save Plus mode because the phone user pressed the Select key.
• When the phone is repowered by the attached switch.
• When the Phone Off Time is reached but the phone is in use.
The range of the field is 20 to 1440 minutes.
The default value is 60 minutes.
When enabled, instructs the phone to play an audible alert starting 10 minutes before the time
that the Phone Off Time field specifies.
The audible alert uses the phone ringtone, which briefly plays at specific times during the
10-minute alerting period. The alerting ringtone plays at the user-designated volume level. The
audible alert schedule is:
• At 10 minutes before power down, play the ringtone four times.
• At 7 minutes before power down, play the ringtone four times.
• At 4 minutes before power down, play the ringtone four times.
• At 30 seconds before power down, play the ringtone 15 times or until the phone powers
off.
This check box applies only if the Enable Power Save Plus list box has one or more days selected.