Schedule Power Save Plus (EnergyWise) on Cisco IP Phone

To reduce power consumption, configure the phone to sleep (power down) and wake (power up) if your system
includes an EnergyWise controller.
You configure settings in Cisco Unified Communications Manager Administration to enable EnergyWise and
configure sleep and wake times. These parameters are closely tied to the phone display configuration parameters.
When EnergyWise is enabled and a sleep time is set, the phone sends a request to the switch to wake it up at
the configured time. The switch returns either an acceptance or a rejection of the request. If the switch rejects
the request or if the switch does not reply, the phone does not power down. If the switch accepts the request,
the idle phone goes to sleep, thus reducing the power consumption to a predetermined level. A phone that is
not idle sets an idle timer and goes to sleep after the idle timer expires.
To wake up the phone, press Select. At the scheduled wake time, the system restores power to the phone,
waking it up.
Procedure
Step 1
From the Cisco Unified Communications Manager Administration, select Device > Phone.
Step 2
Locate the phone that you need to set up.
Step 3
Navigate to the Product Specific Configuration area and set the following fields.
Table 13: EnergyWise Configuration Fields
Field
Enable Power Save Plus
Description
Selects the schedule of days for which the phone powers off. Select multiple days by pressing
and holding the Control key while clicking on the days for the schedule.
By default, no days are selected.
When Enable Power Save Plus is checked, you receive a message that warns about emergency
(e911) concerns.
While Power Save Plus Mode (the "Mode") is in effect, endpoints that are configured
Caution
for the mode are disabled for emergency calling and from receiving inbound calls.
By selecting this mode, you agree to the following: (i) You take full responsibility
for providing alternate methods for emergency calling and receiving calls while the
mode is in effect; (ii) Cisco has no liability in connection with your selection of the
mode and all liability in connection with enabling the mode is your responsibility;
and (iii) You fully inform users of the effects of the mode on calls, calling and
otherwise.
To disable Power Save Plus, you must uncheck the Allow EnergyWise Overrides check
Note
box. If the Allow EnergyWise Overrides remains checked but no days are selected in
the Enable Power Save Plus field, Power Save Plus is not disabled.