Setup Menu: Outputs: TS Out: DPM,
8. On the same menu, set the following parameters:
Map Mode
Duplic Mode
Unref
PSI Options
PSI Rate
Svc ID
9. Set the table parameters as follows:
PAT
CAT
PMT
TSDT
NIT
NITO
SDT
SDTO
BAT
EIT
TDT
RST
TOT
DIT
4-82
Model D9854 Advanced Program Receiver Installation and Operation Guide
Continued
Parameter
Parameter
Description
Svc ID & PID
Pkt Copy
Drop
Ctl By Table
Any
Any
Description
Regen
Regen
Regen
Drop
Regen or Drop
Drop
Regen
Drop
Drop
Drop
Pass
Pass
Pass
Pass