12.1.3.3

CentricStor Global System State

Every 300 seconds the Global System State (see the
without SNMP" on page
this trap onto the SNMP Management Station. This trap is designed to control the color of
the ICON. The format of this trap is identical to the CentricStor Trap.
The various bindings are set as follows:
ObjectID:
Specific Trap #:
Var. Binding 1:
Var. Binding 2:
Var. Binding 3:
Var. Binding 4:
The following weights are sent:
1: green
4: yellow
7: red
A MIB call for returning the CentricStor Global System State is not possible.
12.1.3.4

GXCC on the SNMP Management Station

If permitted by the SNMP Management Station, the GXCC can be activated by means of
application launching either with a mouse click or using a start button in order to obtain
further information.
12.1.3.5

Sending a trap to the Management Station

To test the connection, a test trap can be sent after the SNMP trap has been activated on
CentricStor (see the
been made known on the SNMP Management Station. A menu item is provided for this
under sysadm -> sinix_2000 -> snmp -> config -> traps -> send. The following data should
be output on the Management Station:
Var. Binding 1: enterprises.231.2.48.2.1.2: CS-MsgManager
Var. Binding 2: enterprises.231.2.48.2.1.3: VLP0
Var. Binding 3: enterprises.231.2.48.2.1.4: 6 (=weight)
Var. Binding 4: enterprises.231.2.48.2.1.5: Test message
U41117-J-Z125-7-76
549) of CentricStor is sent via a trap. It is not meaningful to write
enterprises.231.2.48.2.0
0
enterprises.231.2.48.2.1.2: CS-SNMP_Mgr
(the CentricStor tool which sends the trap)
enterprises.231.2.48.2.1.3: device on which the state of CentricStor
was built.
enterprises.231.2.48.2.1.4: weight of the Global State Trap
enterprises.231.2.48.2.1.5: Text: "Global System State"
CentricStor is ready
A part of CentricStor is defective, but CentricStor can go on working with
restrictions.
CentricStor cannot work correctly.
section "Activating the configuration" on page