Message lines
SXRP051
RPLM(#51): ERROR: <pds> reports errno = <num> ( <string> ) on PV <name>
Meaning
The PDS has detected an error.
Response
Notify maintenance staff if necessary.
SXRP052
RPLM(#52): NOTICE: PLS reports VOLUME ERROR for PV <pv>, PV-file will be removed
Meaning
The physical library does not know this PV.
Response
Check the VSN of the PV, correct it, and notify the robot of the new VSN.
9.2.17 SXSB... (Sadm Driver: SCSI bus error)

SXSB001

chim1 (sadm9): SCSI-Bus reset
None
Meaning
This message is part of a message complex (see the
Controller" on page
SXSB003
chim1 (sadm9): reinit of target <t> lun <l> failed
None
Meaning
One of the targets could not be initialized again after a bus reset. As this initialization is
repeated automatically, this message can be ignored.
SXSB005
chim1 (sadm9): RESETTING CONTROLLER
None
Meaning
This message is part of a message complex (see the
Controller" on page
494
542).
542).
Explanation of console messages
section "Bus Reset for SCSI
section "Bus Reset for SCSI
U41117-J-Z125-7-76