Sxse - Fujitsu Siemens Computers pmn User Manual

Centricstor v3.1d user guide
Table of Contents

Advertisement

Message lines
SXSD017
shd<k>t<ctl>:
ALERT
Meaning
Irrecoverable read errors occur sporadically on the FibreCAT RAID disk array despite
mirroring.
Response
Notify maintenance staff.
SXSD018
shd<k>t<ctl>: Target vanished
See the
9.2.20 SXSE... (EXABYTE Tapes)

SXSE005

WARNING: exa: out of spt, deconfiguring exa
Meaning
The driver could not allocate any virtual adresses for IO mapping. No tape devices will be
usable for this ISP. Reason: the kernel has been modified. This error does not occur if the
standard kernel is used without any further tuning or modification.
Response
Notify maintenance staff.
SXSE006
mbk<n>t<t>: cmd 1B failed; status <...>
ALERT
This message is part of a message complex (see the
on page
496
cmd "Read" @ blk <n> key "Medium Error" (0x03) asc ....
section "Failover at the RAID system" on page 541
539).
Explanation of console messages
section "Timeout on the MTC drives"
U41117-J-Z125-7-76