Sxsm - Fujitsu Siemens Computers pmn User Manual

Centricstor v3.1d user guide
Table of Contents

Advertisement

Explanation of console messages
9.2.21 SXSM... (Server Management)
The term "sma#" used in this description is a collective term for the process names "sma",
"sma02", "sma03", "sma04", "sma05" and "sma06" which are specified in the error
messages in accordance with the hardware type of the SINIX server.
With the fan messages, the fan IDs <Id> have the following meaning:
SysFanx
Cpux Fan
PSx Fan
All error messages are also recorded in the default log file via V3 logging.

SXSM001

sma#: Power supply <Id> is not present
ALERT
Meaning
Redundant power supply module <Id> has not been installed.
Response
Notify maintenance staff.
SXSM002
sma#: Power supply <Id> is present and failed
ALERT
Meaning
Redundant power supply module <Id> has failed.
Response
Notify maintenance staff.
SXSM004
sma#: Fan <Id> is not working
ALERT
Meaning
Fan <Id> has failed and must be replaced. If the fan is inoperable for more than 3 minutes,
the SINIX system is shut down and the server deactivated to prevent the server from
overheating.
Response
Notify maintenance staff.
SXSM006
sma#: *** SHUTDOWN *** (Shutdown because of defective Fan [<Id>])
ALERT
Meaning
The SINIX system is shut down because a fan is defective and the server deactivated to
prevent the server from overheating.
U41117-J-Z125-7-76
System fan number x (e.g. SysFan3)
CPU fan number x (e.g. Cpu0 Fan)
Power supply fan number x (e.g. PS1 Fan)
Message lines
497

Advertisement

Table of Contents
loading

This manual is also suitable for:

Centricstor v3.1d

Table of Contents