Explanation of console messages
SXPL021
LM(#21): NOTICE: Reorganisation failed for LV <LV-name> on PV <PV-name>,
continue
Meaning
A reorganization operation initiated by the user encountered an error. The logical volume
<LV-name> could not be read from the physical volume <PV-name>. An attempt will be
made to move any other logical volumes from this physical volume.
Response
If this message occurs repeatedly, check whether the physical volume is accessible. There
may be a media error. The logical volume mentioned in the error message is not currently
available.
SXPL022
PLM(#22): ERROR: PLS reports VSN_NOEXIST on PDS <PDS-name>, PV <PV-name>
Meaning
The robot does not recognize the physical volume <PV-name>.
Response
This may be temporary. You should nevertheless check whether the relevant tape cartridge
is known to the robot. Notify maintenance staff if necessary.
SXPL023
PLM(#23): ERROR: <PDS-name> has been disabled
Meaning
An error, categorized by the PLM as a drive error, has occurred. The corresponding drive
is logically deactivated. This may also happen if the DTV filesystem is not mounted on the
PDS computer or the robot is unable to operate the drive.
Response
- Check whether the filesystems are correctly mounted
- Sense byte analysis of the corresponding PDS
- Reactivate the PDS using the XTCC function "Insert Drive"
Notify maintenance staff if necessary.
SXPL024
PLM(#24): NOTICE: Invalidation of PV-Header failed for PV <name>, PV-Group
<group>
Meaning
The header on the physical volume could not be invalidated.
Response
- Check the cause of error (PLS, PDS).
- Repeat the delete job with the -f option.
Notify maintenance staff.