Fujitsu Siemens Computers pmn User Manual page 532

Centricstor v3.1d user guide
Table of Contents

Advertisement

Message lines
SXVW053
VLPWATCH: NOTICE: VW(#053) AutoVLP-Failover: system error of getx2kvp()!
Meaning
An error occurred while checking the license.
Response
Check the license.
SXVW054
VLPWATCH: NOTICE: VW(#054) AutoVLP-Failover: error of %d=getx2kvp()!
Meaning
An error occurred while checking the license.
Response
Check the license.
SXVW055
VLPWATCH: ERROR: VW(#055) AutoVLP-Failover: no reboot to switch!: %s
Meaning
The statement for the explicit switchover was issued on the VLP. The SVLP is not available
or the VLPwatch daemon is not running:
%s = SVLP is not alive!
%s = SVLP is not alive (%d Seconds)!
%s = SVLP (%s) is alive; VLPwatch on %s not running!
Response
The SVLP must be checked and the AutoVLP function must be activated!
SXVW056
VLPWATCH: ERROR: VW(#056) AutoVLP-Failover: no reboot to switch: not a VLP!
Meaning
The statement for the explicit switchover was issued on an SVLP. However, it may only be
issued on the VLP.
Response
Issue the statement for explicit switchover ("swap master") on the VLP.
SXVW057
VLPWATCH: ALERT: VW(#057) AutoVLP-Failover: LAN_0 connection is DOWN on SVLP;
Failover not functional!
Meaning
The SVLP has no connection to the internal LAN. The AutoVLP failover function is not wor-
king.
Response
Investigate and correct the LAN connection problem.
532
Explanation of console messages
U41117-J-Z125-7-76

Advertisement

Table of Contents
loading

This manual is also suitable for:

Centricstor v3.1d

Table of Contents